WEKO3
アイテム
{"_buckets": {"deposit": "494aecff-e43d-4da0-91da-53c866d2cccc"}, "_deposit": {"created_by": 3, "id": "1060", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "1060"}, "status": "published"}, "_oai": {"id": "oai:mdu.repo.nii.ac.jp:00001060", "sets": ["86"]}, "author_link": ["0"], "item_2_alternative_title_1": {"attribute_name": "その他(別言語等)のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "The Histological Observation of the Biocompatibility of Titanium and Nickel-Titanium Alloy"}]}, "item_2_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1991-08-31", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "200", "bibliographicPageStart": "189", "bibliographicVolumeNumber": "17", "bibliographic_titles": [{"bibliographic_title": "松本歯学"}]}]}, "item_2_description_19": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_2_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In this study we observed the biocompatibility of titanium and Ti-Ni alloy (Shape Memory alloy). Slide glass, a piece of nickel, a piece of Ti-Ni alloy, and a shape memory alloy root type implant were embeded in the mandibule of Japanese monkeys. The results were that, althogh nickel is a detrimental material in vivo, the titanium-nickel alloy (Shape Memory alloy) is a biocompatible one. When the Shape Memory Implant was inserted, the trabecular bones surrounded the implant and the bone tissues a chered tightly to it without the fibrous connective tissues. Because of the in situ of the oxidized membrane on the titanium-nickel alloy, we come to a unanimous conclusion about the use of titanium-nickel alloy. The titanium-nickel alloy implant (shape Memory Alloy Implant) is a useful implant for the dental implant system.", "subitem_description_type": "Abstract"}]}, "item_2_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "松本歯科大学学会"}]}, "item_2_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00232590", "subitem_source_identifier_type": "NCID"}]}, "item_2_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0385-1613", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "崔, 峻宇"}, {"creatorName": "吉沢, 英樹"}, {"creatorName": "鈴木, 和夫"}, {"creatorName": "鷹股, 哲也"}, {"creatorName": "福与, 碩夫"}], "nameIdentifiers": [{"nameIdentifier": "0", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2012-05-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "matsumoto_shigaku_17-02-05.pdf", "filesize": [{"value": "3.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 3400000.0, "url": {"label": "matsumoto_shigaku_17-02-05.pdf", "url": "https://mdu.repo.nii.ac.jp/record/1060/files/matsumoto_shigaku_17-02-05.pdf"}, "version_id": "e7681f0a-f0af-42a2-8c29-67e43457eda0"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "チタンおよびチタン・ニッケル合金", "subitem_subject_scheme": "Other"}, {"subitem_subject": "生体親和性", "subitem_subject_scheme": "Other"}, {"subitem_subject": "組織学的観察", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "チタンおよびチタン・ニッケル合金の生体親和性に関する組織学的観察", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "チタンおよびチタン・ニッケル合金の生体親和性に関する組織学的観察"}]}, "item_type_id": "2", "owner": "3", "path": ["86"], "permalink_uri": "https://mdu.repo.nii.ac.jp/records/1060", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-05-24"}, "publish_date": "2012-05-24", "publish_status": "0", "recid": "1060", "relation": {}, "relation_version_is_last": true, "title": ["チタンおよびチタン・ニッケル合金の生体親和性に関する組織学的観察"], "weko_shared_id": -1}
チタンおよびチタン・ニッケル合金の生体親和性に関する組織学的観察
https://mdu.repo.nii.ac.jp/records/1060
https://mdu.repo.nii.ac.jp/records/1060f086012a-28f5-4c9e-a3b1-c2219937f6dd
名前 / ファイル | ライセンス | アクション |
---|---|---|
matsumoto_shigaku_17-02-05.pdf (3.4 MB)
|
|
Item type | Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-05-24 | |||||
タイトル | ||||||
タイトル | チタンおよびチタン・ニッケル合金の生体親和性に関する組織学的観察 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | チタンおよびチタン・ニッケル合金 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 生体親和性 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 組織学的観察 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | The Histological Observation of the Biocompatibility of Titanium and Nickel-Titanium Alloy | |||||
著者 |
崔, 峻宇
× 崔, 峻宇 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In this study we observed the biocompatibility of titanium and Ti-Ni alloy (Shape Memory alloy). Slide glass, a piece of nickel, a piece of Ti-Ni alloy, and a shape memory alloy root type implant were embeded in the mandibule of Japanese monkeys. The results were that, althogh nickel is a detrimental material in vivo, the titanium-nickel alloy (Shape Memory alloy) is a biocompatible one. When the Shape Memory Implant was inserted, the trabecular bones surrounded the implant and the bone tissues a chered tightly to it without the fibrous connective tissues. Because of the in situ of the oxidized membrane on the titanium-nickel alloy, we come to a unanimous conclusion about the use of titanium-nickel alloy. The titanium-nickel alloy implant (shape Memory Alloy Implant) is a useful implant for the dental implant system. | |||||
書誌情報 |
松本歯学 巻 17, 号 2, p. 189-200, 発行日 1991-08-31 |
|||||
出版者 | ||||||
出版者 | 松本歯科大学学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0385-1613 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00232590 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |