WEKO3
アイテム
{"_buckets": {"deposit": "116f27e6-124b-4e8b-85af-c4b8eb8528e6"}, "_deposit": {"created_by": 3, "id": "1063", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "1063"}, "status": "published"}, "_oai": {"id": "oai:mdu.repo.nii.ac.jp:00001063", "sets": ["86"]}, "author_link": ["0"], "item_2_alternative_title_1": {"attribute_name": "その他(別言語等)のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "The Three Dimentional Reconstruction of CT Images for the Maxillo-Facial Lesions"}]}, "item_2_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1991-08-31", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "221", "bibliographicPageStart": "215", "bibliographicVolumeNumber": "17", "bibliographic_titles": [{"bibliographic_title": "松本歯学"}]}]}, "item_2_description_19": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_2_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Three-dimensional reconstruction of CT images has been actively pursued in recent years. In Japan, soft ware has been developed for 3-D image reconstruction and, as a result, several reports have also been done. We have used 3-D soft ware incorporated into CT scanner at MDC since 1988. This soft ware had originally been developed by Toshiba Medical Co. as a part of the image processing system for the TCT-60A-EX and TCT-700S (CT scanner, Toshiba). It performs with easy handling, 3-D image reconstruction in a short time. The shading, lighting, and viewing direction of 3-D images and set at will. Moreover, 3D-distance, angle and volume are measurable on the 3-D images. We will report here the outline of the procedure and the optimal conditions for image processing, we will also show some clinical cases.", "subitem_description_type": "Abstract"}]}, "item_2_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "松本歯科大学学会"}]}, "item_2_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00232590", "subitem_source_identifier_type": "NCID"}]}, "item_2_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0385-1613", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "深澤, 常克"}, {"creatorName": "児玉, 建三"}, {"creatorName": "長内, 剛"}, {"creatorName": "馬瀬, 直通"}, {"creatorName": "丸山, 清"}], "nameIdentifiers": [{"nameIdentifier": "0", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2012-05-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "matsumoto_shigaku_17-02-08.pdf", "filesize": [{"value": "2.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2000000.0, "url": {"label": "matsumoto_shigaku_17-02-08.pdf", "url": "https://mdu.repo.nii.ac.jp/record/1063/files/matsumoto_shigaku_17-02-08.pdf"}, "version_id": "c637dadf-7977-4b4f-add5-e76cde23febf"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "CT", "subitem_subject_scheme": "Other"}, {"subitem_subject": "三次元画像", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ソフトウェア", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "顎・顔面病変のためのCT三次元画像表示", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "顎・顔面病変のためのCT三次元画像表示"}]}, "item_type_id": "2", "owner": "3", "path": ["86"], "permalink_uri": "https://mdu.repo.nii.ac.jp/records/1063", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-05-24"}, "publish_date": "2012-05-24", "publish_status": "0", "recid": "1063", "relation": {}, "relation_version_is_last": true, "title": ["顎・顔面病変のためのCT三次元画像表示"], "weko_shared_id": -1}
顎・顔面病変のためのCT三次元画像表示
https://mdu.repo.nii.ac.jp/records/1063
https://mdu.repo.nii.ac.jp/records/1063af6e0055-0c9d-4e1f-a081-a6709ddd0622
名前 / ファイル | ライセンス | アクション |
---|---|---|
matsumoto_shigaku_17-02-08.pdf (2.0 MB)
|
|
Item type | Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-05-24 | |||||
タイトル | ||||||
タイトル | 顎・顔面病変のためのCT三次元画像表示 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | CT | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 三次元画像 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ソフトウェア | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | The Three Dimentional Reconstruction of CT Images for the Maxillo-Facial Lesions | |||||
著者 |
深澤, 常克
× 深澤, 常克 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Three-dimensional reconstruction of CT images has been actively pursued in recent years. In Japan, soft ware has been developed for 3-D image reconstruction and, as a result, several reports have also been done. We have used 3-D soft ware incorporated into CT scanner at MDC since 1988. This soft ware had originally been developed by Toshiba Medical Co. as a part of the image processing system for the TCT-60A-EX and TCT-700S (CT scanner, Toshiba). It performs with easy handling, 3-D image reconstruction in a short time. The shading, lighting, and viewing direction of 3-D images and set at will. Moreover, 3D-distance, angle and volume are measurable on the 3-D images. We will report here the outline of the procedure and the optimal conditions for image processing, we will also show some clinical cases. | |||||
書誌情報 |
松本歯学 巻 17, 号 2, p. 215-221, 発行日 1991-08-31 |
|||||
出版者 | ||||||
出版者 | 松本歯科大学学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0385-1613 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00232590 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |