<?xml version='1.0' encoding='UTF-8'?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-03-06T08:11:44Z</responseDate>
  <request metadataPrefix="oai_dc" verb="GetRecord" identifier="oai:mdu.repo.nii.ac.jp:00001060">https://mdu.repo.nii.ac.jp/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:mdu.repo.nii.ac.jp:00001060</identifier>
        <datestamp>2023-06-19T08:23:17Z</datestamp>
        <setSpec>1:44:86</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns="http://www.w3.org/2001/XMLSchema" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>The Histological Observation of the Biocompatibility of Titanium and Nickel-Titanium Alloy</dc:title>
          <dc:title>チタンおよびチタン・ニッケル合金の生体親和性に関する組織学的観察</dc:title>
          <dc:creator>崔, 峻宇</dc:creator>
          <dc:creator>吉沢, 英樹</dc:creator>
          <dc:creator>鈴木, 和夫</dc:creator>
          <dc:creator>鷹股, 哲也</dc:creator>
          <dc:creator>福与, 碩夫</dc:creator>
          <dc:subject>チタンおよびチタン・ニッケル合金</dc:subject>
          <dc:subject>生体親和性</dc:subject>
          <dc:subject>組織学的観察</dc:subject>
          <dc:description>application/pdf</dc:description>
          <dc:description>In this study we observed the biocompatibility of titanium and Ti-Ni alloy (Shape Memory alloy). Slide glass, a piece of nickel, a piece of Ti-Ni alloy, and a shape memory alloy root type implant were embeded in the mandibule of Japanese monkeys. The results were that, althogh nickel is a detrimental material in vivo, the titanium-nickel alloy (Shape Memory alloy) is a biocompatible one. When the Shape Memory Implant was inserted, the trabecular bones surrounded the implant and the bone tissues a chered tightly to it without the fibrous connective tissues. Because of the in situ of the oxidized membrane on the titanium-nickel alloy, we come to a unanimous conclusion about the use of titanium-nickel alloy. The titanium-nickel alloy implant (shape Memory Alloy Implant) is a useful implant for the dental implant system.</dc:description>
          <dc:description>journal article</dc:description>
          <dc:publisher>松本歯科大学学会</dc:publisher>
          <dc:date>1991-08-31</dc:date>
          <dc:type>VoR</dc:type>
          <dc:format>application/pdf</dc:format>
          <dc:identifier>松本歯学</dc:identifier>
          <dc:identifier>2</dc:identifier>
          <dc:identifier>17</dc:identifier>
          <dc:identifier>189</dc:identifier>
          <dc:identifier>200</dc:identifier>
          <dc:identifier>AN00232590</dc:identifier>
          <dc:identifier>0385-1613</dc:identifier>
          <dc:identifier>https://mdu.repo.nii.ac.jp/record/1060/files/matsumoto_shigaku_17-02-05.pdf</dc:identifier>
          <dc:identifier>https://mdu.repo.nii.ac.jp/records/1060</dc:identifier>
          <dc:language>jpn</dc:language>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
