{"created":"2023-06-19T07:38:17.464823+00:00","id":1267,"links":{},"metadata":{"_buckets":{"deposit":"f708a6d1-ac39-471e-8386-2614e0605f8f"},"_deposit":{"created_by":3,"id":"1267","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"1267"},"status":"published"},"_oai":{"id":"oai:mdu.repo.nii.ac.jp:00001267","sets":["1:48:75"]},"author_link":["0"],"item_2_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"The Study of the Cylindrical Type of Endosteal Implants"}]},"item_2_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1987-04-30","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"82","bibliographicPageStart":"64","bibliographicVolumeNumber":"13","bibliographic_titles":[{"bibliographic_title":"松本歯学"}]}]},"item_2_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"There are several different types and materials that are used in the endosteal implant, and recently, the root type implant has been used. In order to be acceptable as a material for implant, it is essential that it does not initiate an unacceptable inflammatory response in the tissue, and that it is biocompatible. In the present study, the acceptability of titanium for root type implants was examined in vivo histopathologically and clinically and its functional problems resulting from occlusal stress was considered. The right mandibles of 12 adult dogs, from which premolars had been removed, were used in the present study. After alveoectomy, a newly devised endosteal implant which contained a piece of transplanted bone was inserted and followed with closure of the surgical site. The insertion material was a cylindrical titanium tube approximately 5mm in diameter and 7mm in height. The tube wall was punched with many holes approximately 1mm in diameter. The tube was filled with fresh bone marrow, which is excised from the iliac bone, before insertion. After 3~18 months, the thick connective tissue layer surrownded the metal, and the bone tissue, which grew from spongy bone, came into contact with the metal. Inside the tube, the dense spongy bone was marked by a trabecular bone which enters the tube from the superior, inferior and lateral holes. The entering bone matrix made contact with the remaining transplanted bone.","subitem_description_type":"Abstract"}]},"item_2_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"松本歯科大学学会"}]},"item_2_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00232590","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-1613","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"重浦, 英正"},{"creatorName":"吉沢, 英樹"},{"creatorName":"鈴木, 和夫"}],"nameIdentifiers":[{"nameIdentifier":"0","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2012-05-24"}],"displaytype":"detail","filename":"matsumoto_shigaku_13-01-06.pdf","filesize":[{"value":"5.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"matsumoto_shigaku_13-01-06.pdf","url":"https://mdu.repo.nii.ac.jp/record/1267/files/matsumoto_shigaku_13-01-06.pdf"},"version_id":"c4949203-ba7c-4b91-ab3a-f7907bcb9e00"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"組織構造","subitem_subject_scheme":"Other"},{"subitem_subject":"骨形成","subitem_subject_scheme":"Other"},{"subitem_subject":"インプラント","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"シリンダー型骨内インプラントの実験的研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"シリンダー型骨内インプラントの実験的研究"}]},"item_type_id":"2","owner":"3","path":["75"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-05-24"},"publish_date":"2012-05-24","publish_status":"0","recid":"1267","relation_version_is_last":true,"title":["シリンダー型骨内インプラントの実験的研究"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T08:18:31.594011+00:00"}