{"created":"2023-06-19T07:38:39.548075+00:00","id":1698,"links":{},"metadata":{"_buckets":{"deposit":"58a6701b-e540-40a0-9ce6-4f6d166916eb"},"_deposit":{"created_by":3,"id":"1698","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"1698"},"status":"published"},"_oai":{"id":"oai:mdu.repo.nii.ac.jp:00001698","sets":["1:12:60"]},"author_link":["211"],"item_2_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"The Study of Strain on the Trabecular Bone Surrounding the Blade Implants by Means of the Strain Gauges Method"}]},"item_2_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1981-12-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"193","bibliographicPageStart":"181","bibliographicVolumeNumber":"7","bibliographic_titles":[{"bibliographic_title":"松本歯学"}]}]},"item_2_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The strain of the trabecular bone surrounding a blade-vent type endosteal implant was evaluated by means of wire strain gauges, when loading from various directions was applied to the head portion of the implant embedded in the mandibular bone of humankind (dried bone) and Japanese monkey. The vertical load on the implant created compression within the bone adjacent to the lateral surface of the implant. Furthermore, it was found that continual vertical loads created severe compression within the bone adjacent to the apical portion of the implant and inside of the vent. When the horizontal load was applied bucco-lingually to the implant, intense strains were found within the bone adjacent to the buccal and lingual surfaces of the implant. The loads created compression within the bone at the loading side, and distension within the bone at the tensive side of the implant. Especially at the tensive side, the distension of the bone was severe. When the horizontal load was applied mesiodistally to the implant, the compression or distension was revealed within the bone adjacent to the mesial and distal sides of the implant. Although distension of the bone adjacent to the neck of the implant was detected, there was no or little strain within the bone adjacent to the buccal and lingual sides and to the apical portion of the implant. These results indicate that the masticatory forces added to the implant denture should be transmitted nearly directly through the implant to the trabecular bone surrounding it. And moreover, it seems that in the construction of the implant denture the lateral forces of bucco-lingual direction should be considered very seriously, because the horizontal load applied bucco-lingually to the implant created intense strains within the bone adjacent to the buccal and lingual surfaces of the implant.","subitem_description_type":"Abstract"}]},"item_2_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"松本歯科大学学会"}]},"item_2_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00232590","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-1613","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"塚本, 勝彦"}],"nameIdentifiers":[{"nameIdentifier":"211","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2013-10-30"}],"displaytype":"detail","filename":"matsumoto_shigaku_07-02-02.pdf","filesize":[{"value":"1.8 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"matsumoto_shigaku_07-02-02.pdf","url":"https://mdu.repo.nii.ac.jp/record/1698/files/matsumoto_shigaku_07-02-02.pdf"},"version_id":"861ba86a-71b7-4964-bdf0-11f5c378b055"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ブレード・インプラント周囲骨梁のストレンゲージ法による歪みについての研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ブレード・インプラント周囲骨梁のストレンゲージ法による歪みについての研究"}]},"item_type_id":"2","owner":"3","path":["60"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-10-30"},"publish_date":"2013-10-30","publish_status":"0","recid":"1698","relation_version_is_last":true,"title":["ブレード・インプラント周囲骨梁のストレンゲージ法による歪みについての研究"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T08:09:04.173228+00:00"}