{"created":"2023-06-19T07:38:44.418249+00:00","id":2267,"links":{},"metadata":{"_buckets":{"deposit":"9efa607b-00f9-4856-bbee-d1179ae8ae36"},"_deposit":{"created_by":3,"id":"2267","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"2267"},"status":"published"},"_oai":{"id":"oai:mdu.repo.nii.ac.jp:00002267","sets":["1:198:199"]},"author_link":["2299","2298","2291","2295","2300","2292","2297","2296","2293","2294"],"item_10001_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Mechanical properties and stability of the porous zirconia"}]},"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-06-30","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"18","bibliographicPageStart":"13","bibliographicVolumeNumber":"40","bibliographic_titles":[{"bibliographic_title":"松本歯学"},{"bibliographic_title":"Journal of the Matsumoto Dental University Society","bibliographic_titleLang":"en"}]}]},"item_10001_creator_3":{"attribute_name":"著者別名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"FUJIMORI, KAZUKI"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KAWASE, YUUJI"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"YOSHIDA, TAKAMITSU"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"NAGASAWA, SAKAE"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"ITO, MICHIO"}],"nameIdentifiers":[{}]}]},"item_10001_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"It has been reported that osseointegration between bone and a titanium implant material is affected by the titanium surface condition. The same theory is applied to a ceramic implant material. It is considered that dispersing pores on the ceramic surface facilitates osseointegration with bone. A double–layered implant material consisting of pores on the\nsurface and a dense core was designed. The purpose of the present research was released and the mechanical strength of zirconia with 30% porosity. The bending strength before and after immersion in 1 % lactic acid solution, released component measurement. The results were as follows: Y2O3 partiall stabilized Zirconia showed a higher bending strength before and after immersion in lactic acid solution than CaO partiall stabilized Zirconia. The bending strength\nof CaO partiall stabilized Zirconia decreased greatly after immersion. The strain was larger in Y2O3 partiall stabilized Zirconia than CaO partiall stabilized Zirconia. The amounts of dissolved component were higher in CaO partiall stabilized Zirconia than with Y2O3. It was preferable to use Y2O3 partiall stabilized Zirconia for the implant material.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"松本歯科大学学会"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-1613","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"藤森, 一樹"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"河瀬, 雄治"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"吉田, 貴光"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"永沢, 栄"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"伊藤, 充雄"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2014-09-11"}],"displaytype":"detail","filename":"matsumoto_shigaku40-1-02.pdf","filesize":[{"value":"6.9 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"matsumoto_shigaku40-1-02.pdf","url":"https://mdu.repo.nii.ac.jp/record/2267/files/matsumoto_shigaku40-1-02.pdf"},"version_id":"04ef216d-1885-4d01-8e22-6c27c9b44c0f"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"人工歯根","subitem_subject_scheme":"Other"},{"subitem_subject":"ジルコニア","subitem_subject_scheme":"Other"},{"subitem_subject":"機械的性質","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"多孔質ジルコニアの安定性と機械的性質","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"多孔質ジルコニアの安定性と機械的性質"}]},"item_type_id":"10001","owner":"3","path":["199"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-09-11"},"publish_date":"2014-09-11","publish_status":"0","recid":"2267","relation_version_is_last":true,"title":["多孔質ジルコニアの安定性と機械的性質"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-19T08:06:30.135855+00:00"}