{"created":"2023-06-19T07:38:46.478782+00:00","id":2354,"links":{},"metadata":{"_buckets":{"deposit":"2cf1f873-c13c-4795-b06f-7598e3591741"},"_deposit":{"created_by":3,"id":"2354","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"2354"},"status":"published"},"_oai":{"id":"oai:mdu.repo.nii.ac.jp:00002354","sets":["1:198:216"]},"author_link":["2561","2562"],"item_10001_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Analysis of the causes of defluxion of dental implants over a 15–year period in our clinic"}]},"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-12-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"104","bibliographicPageStart":"91","bibliographicVolumeNumber":"40","bibliographic_titles":[{"bibliographic_title":"松本歯学"},{"bibliographic_title":"Journal of the Matsumoto Dental University Society","bibliographic_titleLang":"en"}]}]},"item_10001_creator_3":{"attribute_name":"著者別名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"IKUO, SUZUKI"}],"nameIdentifiers":[{}]}]},"item_10001_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Objective: The current accessibility of large volumes of clinical data has led to increasedlongevity of dental implants, and expectations surrounding prosthetic survival are rising.However, there are few case reports regarding the causes of defluxion of dental implants.Due to the significance of such cases in clinical practice, we report herein a survey investigatingthe causes of defluxion of dental implants in our clinic. Methods: Patients who had been fitted with a Brånemark or Replace implant in ourclinic between January 1997 and October 2012 and who were recalled between October 2011and October 2012 (1₅8 patients, 4₅8 implants) were investigated to determine the causes ofdefluxion of their implants and 10 potential related factors. Results: Defluxion occurred in a total of 19 of the 4₅8 implants (4.1%), ranging from asearly as 26 days post–insertion in an unloaded implant to as late as 4,269 days post–insertionin a case of implant fracture. Univariate and multivariate analysis revealed a greaterincidence of implant defluxion among men compared to women (P = 0.022), and a significantlygreater incidence for implant overdentures compared to simple prosthetic designs,such as crowns, linked crowns, and bridges (P=0.004). Conclusion: The present findings reaffirmed aspects of dental implant fitting that requireattention in clinical practice to ensure longevity, particularly prosthetic design andfitting method, as well as the effects of smoking. However, a multicenter survey is requiredto provide further evidence and support these findings.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"松本歯科大学学会"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-1613","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"鈴木, 郁夫"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-04-13"}],"displaytype":"detail","filename":"matsumoto_shigaku40-2-01.pdf","filesize":[{"value":"1.6 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"matsumoto_shigaku40-2-01.pdf","url":"https://mdu.repo.nii.ac.jp/record/2354/files/matsumoto_shigaku40-2-01.pdf"},"version_id":"83650130-e706-433d-85be-902936cd021b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"性別","subitem_subject_scheme":"Other"},{"subitem_subject":"喫煙","subitem_subject_scheme":"Other"},{"subitem_subject":"補綴設計","subitem_subject_scheme":"Other"},{"subitem_subject":"予後解析","subitem_subject_scheme":"Other"},{"subitem_subject":"インプラント","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"当施設における15年間のインプラントの脱落原因に関する解析","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"当施設における15年間のインプラントの脱落原因に関する解析"}]},"item_type_id":"10001","owner":"3","path":["216"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-04-13"},"publish_date":"2015-04-13","publish_status":"0","recid":"2354","relation_version_is_last":true,"title":["当施設における15年間のインプラントの脱落原因に関する解析"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-19T08:06:16.404131+00:00"}