{"created":"2023-06-19T07:39:12.207370+00:00","id":2889,"links":{},"metadata":{"_buckets":{"deposit":"e373b704-5546-40a4-b7b0-dc5c5198440a"},"_deposit":{"created_by":3,"id":"2889","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"2889"},"status":"published"},"_oai":{"id":"oai:mdu.repo.nii.ac.jp:00002889","sets":["1:489:521"]},"author_link":["5111","5110","5114","5109","5117","5115","5116","5108","5112","5113"],"item_10001_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"pH measurement of tissues in living body-The trial examination of needle type pH microsenser applications-"}]},"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-12-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"102","bibliographicPageStart":"97","bibliographicVolumeNumber":"45","bibliographic_titles":[{"bibliographic_title":"松本歯学"},{"bibliographic_title":"Journal of the Matsumoto Dental University Society","bibliographic_titleLang":"en"}]}]},"item_10001_creator_3":{"attribute_name":"著者別名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"KAWAHARA, ICHIRO"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"TSUJIMOTO, MAKOTO"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"MURAKAMI, GOUICHI"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SADAOKA, SUNAO"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KAWAHARA, YOSHIMI"}],"nameIdentifiers":[{}]}]},"item_10001_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Even today, pH measurement of living tissue in a clinical environment has been difficult. In this study, we succeeded in measuring the pH of living tissue and observing changes over time using an optical fiber coated with a newly developed pH–reactive fluorescent substance. A standardized hole was made in the rat tibia, Poly Ether Ether Ketone (PEEK) and Commercially₇ days. As a result, it was confirmed that the pH of the tissue was increased with CP–tita-nium, in which osseointegration was confirmed, and with PEEK, which imparted surface wettability. In addition, a decrease in pH over time due to tissue damage was also confirmed. From the above, it was confirmed that a needle–type pH microsensor is suitable for measuring the pH of living tissue over time. With this method, the development of new implant materials can be expected. Pure (CP)–titanium were implanted, and the pH change was measured after","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"松本歯科大学学会"}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12684554","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2188-7233","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"川原, 一郎"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"辻本, 真"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"村上, 剛一"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"定岡, 直"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"川原, 良美"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-12-31"}],"displaytype":"detail","filename":"matsumoto_shigaku45-2-01.pdf","filesize":[{"value":"2.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"本文","url":"https://mdu.repo.nii.ac.jp/record/2889/files/matsumoto_shigaku45-2-01.pdf"},"version_id":"4afa950a-3955-4603-b09b-3414f983833c"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"生体組織のpH","subitem_subject_scheme":"Other"},{"subitem_subject":"微小領域のpH","subitem_subject_scheme":"Other"},{"subitem_subject":"オッセオインテグレーション獲得新素材開発","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"生体における微小領域組織のpH測定ーニードル型pHマイクロセンサー応用の報告","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"生体における微小領域組織のpH測定ーニードル型pHマイクロセンサー応用の報告"}]},"item_type_id":"10001","owner":"3","path":["521"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-03-13"},"publish_date":"2020-03-13","publish_status":"0","recid":"2889","relation_version_is_last":true,"title":["生体における微小領域組織のpH測定ーニードル型pHマイクロセンサー応用の報告"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T07:53:31.316416+00:00"}