{"created":"2023-06-19T07:37:17.839288+00:00","id":326,"links":{},"metadata":{"_buckets":{"deposit":"9db21a42-3f9b-467f-9205-a23d85852e59"},"_deposit":{"created_by":3,"id":"326","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"326"},"status":"published"},"_oai":{"id":"oai:mdu.repo.nii.ac.jp:00000326","sets":["1:13:63"]},"author_link":["0"],"item_2_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"A Study on the Color Tone within the Mouth Eighth Report : A comparative study on measurment with Micro-Color-Computer and measurement with the naked eye"}]},"item_2_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1982-06-30","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"107","bibliographicPageStart":"100","bibliographicVolumeNumber":"8","bibliographic_titles":[{"bibliographic_title":"松本歯学"}]}]},"item_2_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In the sixth and the seventh report, shade-guide was measured by using an improved radiation detector. As the result, it was able to conclude that the positional relation between the optical receptor and the light source was within 1~3mm in length. Thus, on this report, it was compared that the correlation of the shade-guide of a testee which had been selected in the Integral Calculus Globe, the measured value, and the value selected by the naked eye. First, the shade-guide on natural teeth of 5 testees was selected with unaided eye in the Integral Calculus Globe. Also shade-guide of the same natural teeth was measured using the improved radiation detector and compared both results. Result: In the range of 1~3mm, the position of the radiation detector which gave the minimum value of Hunter color distinction (△E) was 2mm. Thus, in this experiment, it was concluded that the best radiation detector for measurement of the teeth would be a detector which is placed 2mm far from the tip of the source of radiation.","subitem_description_type":"Abstract"}]},"item_2_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"松本歯科大学学会"}]},"item_2_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00232590","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-1613","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"橋口, 綽徳"},{"creatorName":"神津, 瑛"},{"creatorName":"田村, 睦"},{"creatorName":"山本, 真也"},{"creatorName":"坂口, 賢司"},{"creatorName":"伊比, 篤"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2012-05-23"}],"displaytype":"detail","filename":"matsumoto_shigaku_08-01-11.pdf","filesize":[{"value":"417.1 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"matsumoto_shigaku_08-01-11.pdf","url":"https://mdu.repo.nii.ac.jp/record/326/files/matsumoto_shigaku_08-01-11.pdf"},"version_id":"25d07768-2eae-4b5d-88c6-4d6ab949cae6"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"口腔内の色彩に関する研究 第8報 歯牙におけるMicro-Color-Computerと肉眼的測定値との比較","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"口腔内の色彩に関する研究 第8報 歯牙におけるMicro-Color-Computerと肉眼的測定値との比較"}]},"item_type_id":"2","owner":"3","path":["63"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-05-23"},"publish_date":"2012-05-23","publish_status":"0","recid":"326","relation_version_is_last":true,"title":["口腔内の色彩に関する研究 第8報 歯牙におけるMicro-Color-Computerと肉眼的測定値との比較"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T08:41:10.603900+00:00"}