{"created":"2023-06-19T07:37:30.135619+00:00","id":517,"links":{},"metadata":{"_buckets":{"deposit":"cf9958bd-fedf-4ee6-b5ae-a08b0927c0ea"},"_deposit":{"created_by":3,"id":"517","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"517"},"status":"published"},"_oai":{"id":"oai:mdu.repo.nii.ac.jp:00000517","sets":["1:31:122"]},"author_link":["0"],"item_2_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"The mechanical properties of the titanium for implant materials : An influence by the purity"}]},"item_2_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-08-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"154","bibliographicPageStart":"149","bibliographicVolumeNumber":"31","bibliographic_titles":[{"bibliographic_title":"松本歯学"}]}]},"item_2_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Commercially available titanium materials are classified on a standard scale form 1 to 4. The standard is based on the amount of Oxygen, Nitrogen, and Iron contained in the titanium. Recently, implant material made of type 4 titanium, has been marketed. This study compares several mechanical properties including tensile strength, elongation, yield strength, energy to break and hardness between type 2 and type 4. The followings conclusions were obtained: The tensile strength, yield strength, and energy to break of type 4 are higher than those of type 2. Elongation of type 4 is less than that of type 2. Hardness of type 2 is than that of type 4. Overall evaluations of mechanical properties indicate that pure titanium type 4 is superior to type 2 as an implant material.","subitem_description_type":"Abstract"}]},"item_2_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"松本歯科大学学会"}]},"item_2_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00232590","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-1613","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小野, 擴仁"},{"creatorName":"早野, 圭吾"},{"creatorName":"平, 晃一"},{"creatorName":"永沢, 栄"},{"creatorName":"伊藤, 充雄"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2012-05-24"}],"displaytype":"detail","filename":"matsumoto_shigaku_31-02-03.pdf","filesize":[{"value":"1.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"matsumoto_shigaku_31-02-03.pdf","url":"https://mdu.repo.nii.ac.jp/record/517/files/matsumoto_shigaku_31-02-03.pdf"},"version_id":"d977f14e-4f78-4616-addf-f14da847301d"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"チタン","subitem_subject_scheme":"Other"},{"subitem_subject":"インプラント","subitem_subject_scheme":"Other"},{"subitem_subject":"引張強さ","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"インプラント材としてのチタンの機械的性質 : 純度による影響","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"インプラント材としてのチタンの機械的性質 : 純度による影響"}]},"item_type_id":"2","owner":"3","path":["122"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-05-24"},"publish_date":"2012-05-24","publish_status":"0","recid":"517","relation_version_is_last":true,"title":["インプラント材としてのチタンの機械的性質 : 純度による影響"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T08:36:35.491328+00:00"}