{"created":"2023-06-19T07:37:40.551456+00:00","id":683,"links":{},"metadata":{"_buckets":{"deposit":"2bda00f7-0c4e-4891-89de-778ce90d6538"},"_deposit":{"created_by":3,"id":"683","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"683"},"status":"published"},"_oai":{"id":"oai:mdu.repo.nii.ac.jp:00000683","sets":["1:36:109"]},"author_link":["0"],"item_2_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Metal-Elements in Periimplant Tissue Around the Removed Shape-Memory Alloy Implant"}]},"item_2_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2000-04-30","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"24","bibliographicPageStart":"20","bibliographicVolumeNumber":"26","bibliographic_titles":[{"bibliographic_title":"松本歯学"}]}]},"item_2_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Recently titanium and titanium alloys have been widely used for dental implants. Shape-memory alloy implants of these implants are composed of nickel and titanium. This alloy has little adverse effect on the body. We report a case of shape-memory alloy implant removed due to peri-implantitis. Bone loss was observed around the implant due to peri-implant inflammation on X-ray examination. This shape-memory alloy implant was removed, and the soft tissue around the implant was examined using X-ray microanalyzer to analyze the constructive element. These results show that Ni and Sn, dissolute in periimplant tissue.","subitem_description_type":"Abstract"}]},"item_2_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"松本歯科大学学会"}]},"item_2_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00232590","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-1613","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小松, 史"},{"creatorName":"植田, 章夫"},{"creatorName":"上松, 隆司"},{"creatorName":"森, 亮太"},{"creatorName":"山岡, 稔"},{"creatorName":"伊藤, 充雄"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2012-05-24"}],"displaytype":"detail","filename":"matsumoto_shigaku_26-01-03.pdf","filesize":[{"value":"899.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"matsumoto_shigaku_26-01-03.pdf","url":"https://mdu.repo.nii.ac.jp/record/683/files/matsumoto_shigaku_26-01-03.pdf"},"version_id":"173594a0-3ab1-4da1-900e-7c7f05c5d1e0"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"形状記憶","subitem_subject_scheme":"Other"},{"subitem_subject":"周囲軟組織","subitem_subject_scheme":"Other"},{"subitem_subject":"金属イオン","subitem_subject_scheme":"Other"},{"subitem_subject":"摘出","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"摘出した形状記憶インプラント周囲組織の金属イオン","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"摘出した形状記憶インプラント周囲組織の金属イオン"}]},"item_type_id":"2","owner":"3","path":["109"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-05-24"},"publish_date":"2012-05-24","publish_status":"0","recid":"683","relation_version_is_last":true,"title":["摘出した形状記憶インプラント周囲組織の金属イオン"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T08:32:33.344839+00:00"}