{"created":"2023-06-19T07:37:52.401920+00:00","id":864,"links":{},"metadata":{"_buckets":{"deposit":"ca65ef77-9dbf-47b2-a561-c6e39852707d"},"_deposit":{"created_by":3,"id":"864","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"864"},"status":"published"},"_oai":{"id":"oai:mdu.repo.nii.ac.jp:00000864","sets":["1:137:139"]},"author_link":["0"],"item_2_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Mechanical Properties and Metal Dissolution of Laser-Welded Titanium in Physiological Saline and Lactic Acid"}]},"item_2_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1995-08-30","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"147","bibliographicPageStart":"137","bibliographicVolumeNumber":"21","bibliographic_titles":[{"bibliographic_title":"松本歯学"}]}]},"item_2_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This study investigated tensile and releasing properties of titanium samples which were laser welded, plasma welded, and infra-red soldered after immersing test. The main results obtained are as follows; The insertion of a titanium foil was effective to prevent volume reduction during the welding process. It was found that the laser welding reduces tensile properties, especially toughness, and elongation when the samples were immersed and shaken in a physiological saline and in a lactic acid prior to the laser welding. It was also found that, even self-welded titanium samples would be embrittled when they were placed in a corrosive environment over a long period of time. The magnitude of these reductions was more significant with the silver soldering than those with titanium soldering. No evidence of titanium released from the welded portion was observed in a physiological saline, but the released amount of titanium from the welded portion was higher than that from the base metal when it was exposed to a lactic solution. After a silver soldering, a trace amount of titanium was released in a physiological saline after a 6-month immersion test, and the lactic acid's released titanium was remarkably greater with the laser-welded samples. In addition to titanium, it was observed that copper and zinc released from the soldering material were detected in larger amounts.","subitem_description_type":"Abstract"}]},"item_2_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"松本歯科大学学会"}]},"item_2_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00232590","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-1613","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"山岸, 利夫"},{"creatorName":"竹内, 勝泉"},{"creatorName":"森, 厚二"},{"creatorName":"横山, 宏太"},{"creatorName":"伊藤, 充雄"},{"creatorName":"孔, 泰寛"},{"creatorName":"津村, 智信"},{"creatorName":"丹羽, 健"},{"creatorName":"出口, 敏雄"},{"creatorName":"林, 春二"},{"creatorName":"五十嵐, 順正"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2012-05-24"}],"displaytype":"detail","filename":"matsumoto_shigaku_21-02-03.pdf","filesize":[{"value":"691.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"matsumoto_shigaku_21-02-03.pdf","url":"https://mdu.repo.nii.ac.jp/record/864/files/matsumoto_shigaku_21-02-03.pdf"},"version_id":"70fcf08d-9cdd-4677-b1dc-6cd8989aed5e"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"チタン","subitem_subject_scheme":"Other"},{"subitem_subject":"レーザ溶接","subitem_subject_scheme":"Other"},{"subitem_subject":"赤外線ろう付","subitem_subject_scheme":"Other"},{"subitem_subject":"プラズマ溶接","subitem_subject_scheme":"Other"},{"subitem_subject":"浸漬試験","subitem_subject_scheme":"Other"},{"subitem_subject":"溶出","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"レーザ溶接したチタンの浸漬溶液中における機械的性質の経時的変化と溶出について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"レーザ溶接したチタンの浸漬溶液中における機械的性質の経時的変化と溶出について"}]},"item_type_id":"2","owner":"3","path":["139"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-05-24"},"publish_date":"2012-05-24","publish_status":"0","recid":"864","relation_version_is_last":true,"title":["レーザ溶接したチタンの浸漬溶液中における機械的性質の経時的変化と溶出について"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T08:27:55.551046+00:00"}