WEKO3
アイテム
{"_buckets": {"deposit": "9c69d92e-33cf-4273-ba41-ea4311d811c2"}, "_deposit": {"created_by": 3, "id": "739", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "739"}, "status": "published"}, "_oai": {"id": "oai:mdu.repo.nii.ac.jp:00000739", "sets": ["105"]}, "author_link": ["0"], "item_2_alternative_title_1": {"attribute_name": "その他(別言語等)のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Corrosion Test of Dental Alloys by Electrochemical Measurement : Part 3 Application of hydrodynamic voltammetry using a rotating disk electrode"}]}, "item_2_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1998-04-30", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "45", "bibliographicPageStart": "32", "bibliographicVolumeNumber": "24", "bibliographic_titles": [{"bibliographic_title": "松本歯学"}]}]}, "item_2_description_19": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_2_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Hydrodynamic voltammetry is able to increase the accuracy of measurements to rotate the electrode. This study used hydrodynamic voltammetry by means of a rotating disk electrode to examine the corrosion mechanisms of three kinds of pure metals; gold, silver and copper, and six kinds of binary gold alloys. The results were compared with cyclic voltammograms in a statistical system. Hydrodynamic voltammetry provided rapid the steady corrosion reactions. Therefore this method was able to distinguish the elementary processes of chemicals and discharge.", "subitem_description_type": "Abstract"}]}, "item_2_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "松本歯科大学学会"}]}, "item_2_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00232590", "subitem_source_identifier_type": "NCID"}]}, "item_2_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0385-1613", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "洞沢, 功子"}, {"creatorName": "髙橋, 重雄"}], "nameIdentifiers": [{"nameIdentifier": "0", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2012-05-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "matsumoto_shigaku_24-01-03.pdf", "filesize": [{"value": "719.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 719900.0, "url": {"label": "matsumoto_shigaku_24-01-03.pdf", "url": "https://mdu.repo.nii.ac.jp/record/739/files/matsumoto_shigaku_24-01-03.pdf"}, "version_id": "53d30fde-9adf-4730-97e3-975e9e47de89"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "歯科用合金", "subitem_subject_scheme": "Other"}, {"subitem_subject": "腐食", "subitem_subject_scheme": "Other"}, {"subitem_subject": "電気化学測定法", "subitem_subject_scheme": "Other"}, {"subitem_subject": "対流ボルタンメトリ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "回転ディスク電極", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "電気化学測定法による歯科用合金の腐食試験 : その3 回転ディスク電極を用いた対流ボルタンメトリ法の応用", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "電気化学測定法による歯科用合金の腐食試験 : その3 回転ディスク電極を用いた対流ボルタンメトリ法の応用"}]}, "item_type_id": "2", "owner": "3", "path": ["105"], "permalink_uri": "https://mdu.repo.nii.ac.jp/records/739", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-05-24"}, "publish_date": "2012-05-24", "publish_status": "0", "recid": "739", "relation": {}, "relation_version_is_last": true, "title": ["電気化学測定法による歯科用合金の腐食試験 : その3 回転ディスク電極を用いた対流ボルタンメトリ法の応用"], "weko_shared_id": -1}
電気化学測定法による歯科用合金の腐食試験 : その3 回転ディスク電極を用いた対流ボルタンメトリ法の応用
https://mdu.repo.nii.ac.jp/records/739
https://mdu.repo.nii.ac.jp/records/739f438eaa8-11a5-48dc-8495-99fbe55a480b
名前 / ファイル | ライセンス | アクション |
---|---|---|
matsumoto_shigaku_24-01-03.pdf (719.9 kB)
|
|
Item type | Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-05-24 | |||||
タイトル | ||||||
タイトル | 電気化学測定法による歯科用合金の腐食試験 : その3 回転ディスク電極を用いた対流ボルタンメトリ法の応用 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 歯科用合金 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 腐食 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 電気化学測定法 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 対流ボルタンメトリ | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 回転ディスク電極 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | Corrosion Test of Dental Alloys by Electrochemical Measurement : Part 3 Application of hydrodynamic voltammetry using a rotating disk electrode | |||||
著者 |
洞沢, 功子
× 洞沢, 功子 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Hydrodynamic voltammetry is able to increase the accuracy of measurements to rotate the electrode. This study used hydrodynamic voltammetry by means of a rotating disk electrode to examine the corrosion mechanisms of three kinds of pure metals; gold, silver and copper, and six kinds of binary gold alloys. The results were compared with cyclic voltammograms in a statistical system. Hydrodynamic voltammetry provided rapid the steady corrosion reactions. Therefore this method was able to distinguish the elementary processes of chemicals and discharge. | |||||
書誌情報 |
松本歯学 巻 24, 号 1, p. 32-45, 発行日 1998-04-30 |
|||||
出版者 | ||||||
出版者 | 松本歯科大学学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0385-1613 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00232590 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |