WEKO3
アイテム
矯正用材料へのイオン・プレーティングの応用(その1) : アーチワイヤーへの応用
https://mdu.repo.nii.ac.jp/records/1000
https://mdu.repo.nii.ac.jp/records/1000062f7fb9-03b8-4614-bb8e-c4f79a56036c
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| Item type | Journal Article(1) | |||||||
|---|---|---|---|---|---|---|---|---|
| 公開日 | 2012-05-24 | |||||||
| タイトル | ||||||||
| タイトル | 矯正用材料へのイオン・プレーティングの応用(その1) : アーチワイヤーへの応用 | |||||||
| 言語 | ||||||||
| 言語 | jpn | |||||||
| キーワード | ||||||||
| 言語 | en | |||||||
| 主題Scheme | Other | |||||||
| 主題 | Ti-N Ion-plating | |||||||
| キーワード | ||||||||
| 言語 | en | |||||||
| 主題Scheme | Other | |||||||
| 主題 | orthodontic stainless steel wire | |||||||
| キーワード | ||||||||
| 言語 | en | |||||||
| 主題Scheme | Other | |||||||
| 主題 | esthetic | |||||||
| 資源タイプ | ||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||
| 資源タイプ | journal article | |||||||
| その他(別言語等)のタイトル | ||||||||
| その他のタイトル | Application of Ion-plating Technique for Orthodontic Stainless Steel Arch Wire | |||||||
| 著者 |
白井, 竹郎
× 白井, 竹郎
|
|||||||
| 抄録 | ||||||||
| 内容記述タイプ | Abstract | |||||||
| 内容記述 | The purpose of this study was the development of esthetic orthodontic wire. In this study, the authors performed the technique of applying Ti-N Ion-plating to orthodontic stainless steel arch wire. The authors also compared Ion-plated stainless steel wire with the original one by performing a tensile test, and three pointed bending test, as well as test of surface roughness and Vicker's hardness. The conclusion is as follows: 1: A layer of Ion-plate (2μm thickness) was observed in the original stainless steel wire, but the coating layer was not observed an omission or removal with optical or electron microscopes. 2: There was no statistical difference between Ion-plated stainless steel wire and the original one in terms of tensile strength, yield strength, elongation, bending stress, proof stress and surface roughness. 3: A slight difference between Ion-plated stainless steel wire and the original one was observed in the Vicker's hardness test. These results suggest that Ti-N coating produced by means of the Ion-plating technique is effective for clinical use of orthodontic arch wire. | |||||||
| 書誌情報 |
松本歯学 巻 18, 号 3, p. 271-276, 発行日 1992-12-31 |
|||||||
| 出版者 | ||||||||
| 出版者 | 松本歯科大学学会 | |||||||
| ISSN | ||||||||
| 収録物識別子タイプ | ISSN | |||||||
| 収録物識別子 | 0385-1613 | |||||||
| 書誌レコードID | ||||||||
| 収録物識別子タイプ | NCID | |||||||
| 収録物識別子 | AN00232590 | |||||||
| フォーマット | ||||||||
| 内容記述タイプ | Other | |||||||
| 内容記述 | application/pdf | |||||||
| 著者版フラグ | ||||||||
| 出版タイプ | VoR | |||||||
| 出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||