WEKO3
アイテム
各種ディボンディング(矯正用ブラケット撤去)法によるエナメル質表面損傷に関する研究
https://mdu.repo.nii.ac.jp/records/1116
https://mdu.repo.nii.ac.jp/records/11168936e957-1aa9-41a6-ab27-1f355f57e967
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | Journal Article(1) | |||||||
---|---|---|---|---|---|---|---|---|
公開日 | 2012-05-24 | |||||||
タイトル | ||||||||
タイトル | 各種ディボンディング(矯正用ブラケット撤去)法によるエナメル質表面損傷に関する研究 | |||||||
言語 | ||||||||
言語 | jpn | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | 残留レジン | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | ディボンディング | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | 走査型電子顕微鏡(SEM) | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | エナメル質 | |||||||
資源タイプ | ||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||
資源タイプ | journal article | |||||||
その他(別言語等)のタイトル | ||||||||
その他のタイトル | Research on Damage to Enamel Surfaces Made by Various Methods for Debonding | |||||||
著者 |
用松, 忠信
× 用松, 忠信
|
|||||||
抄録 | ||||||||
内容記述タイプ | Abstract | |||||||
内容記述 | The purpose of this study is to investigate effective procedures for debonding after removal of orthodontic brackets. After ordinary acid bath, thirty extracted mandibular incisors were bonded with metal brackets using either 4-META/MMA-TBB resin or Bis-GMA resin. After 48 hours, the brackets were removed with a Debonding Instrument^[○!R] (Unitek). The resin remaining on the tooth surface was removed with the following instruments: ① removing pliers ② hand scaler ③ ultrasonic scaler ④ No.8 steel round bur. Evaluation was based on observations made of the tooth surface with a scanning electron microscope (SEM), and on the feel of each instrument during use. The results are the following: (1) When the removing pliers were used, the enamel surface was observed to have wide abrasive striations made by the edge of pliers. Though the instrument enabled speedy removal of residual resin, it gave considerable impact to the experimental tooth. (2) When the hand scaler was employed, the enamel surface was found to have slender scratches along the working direction. As the operation required considerable force, it placed a heavy load not only on the operator but also on the tooth. (3) When the ultrasonic scaler was applied with strong force, the tooth surface was seen to have a concave wound in the shape of a hemispherical depression. The operation was inefficient as it required a long time. (4) In case of the No.8 steel round bur used at low speed, comparatively shallow scratches were observed widely covering the entire surface where the residual resin had been removed. As this method did not require much force, the operation could be performed efficiently. From the above results, it was felt desirable for the operator to have a good understanding of the characteristics of each instrument, to select it as the occasion calls, and to use it properly. Also, the use of a No.8 steel round bur without excessive pressure to finish resin removal, after initially removing most of the resin with the removing pliers, is especially believed to be clinically effective as a debonding procedure. | |||||||
書誌情報 |
松本歯学 巻 16, 号 1, p. 23-30, 発行日 1990-04-30 |
|||||||
出版者 | ||||||||
出版者 | 松本歯科大学学会 | |||||||
ISSN | ||||||||
収録物識別子タイプ | ISSN | |||||||
収録物識別子 | 0385-1613 | |||||||
書誌レコードID | ||||||||
収録物識別子タイプ | NCID | |||||||
収録物識別子 | AN00232590 | |||||||
フォーマット | ||||||||
内容記述タイプ | Other | |||||||
内容記述 | application/pdf | |||||||
著者版フラグ | ||||||||
出版タイプ | VoR | |||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |