WEKO3
アイテム
Assessment of Gingival Inflammation by Measuring the Capacitance of the Gingival Fluid Using the Periometer
https://mdu.repo.nii.ac.jp/records/1283
https://mdu.repo.nii.ac.jp/records/12838b10cb44-e3ed-4cb1-a1c8-2bf5fc2c3e51
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | Journal Article(1) | |||||||
---|---|---|---|---|---|---|---|---|
公開日 | 2012-05-24 | |||||||
タイトル | ||||||||
タイトル | Assessment of Gingival Inflammation by Measuring the Capacitance of the Gingival Fluid Using the Periometer | |||||||
言語 | en | |||||||
言語 | ||||||||
言語 | eng | |||||||
キーワード | ||||||||
言語 | en | |||||||
主題Scheme | Other | |||||||
主題 | gingival fluid | |||||||
キーワード | ||||||||
言語 | en | |||||||
主題Scheme | Other | |||||||
主題 | Capacitance | |||||||
キーワード | ||||||||
言語 | en | |||||||
主題Scheme | Other | |||||||
主題 | periometer | |||||||
キーワード | ||||||||
言語 | en | |||||||
主題Scheme | Other | |||||||
主題 | periodontal disease | |||||||
キーワード | ||||||||
言語 | en | |||||||
主題Scheme | Other | |||||||
主題 | gingival inflammation | |||||||
資源タイプ | ||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||
資源タイプ | journal article | |||||||
著者 |
OTA, NORIO
× OTA, NORIO
|
|||||||
抄録 | ||||||||
内容記述タイプ | Abstract | |||||||
内容記述 | This study was undertaken to determine a practical method for detection of gingival inflammation by measuring the capacitance of the gingival fluid. The capacitance of gingival fluid was measured in 25 patients with periodontal disease and 13 normal healthy students. The examinations were performed by the author. The correlation between various clinical findings and the capacitance of the gingival fluid was as follows. 1. Statistically significant correlations were observed between the capacitance of the gingival fluid and the plaque index, gingival index, gingival bleeding index, and pocket depths (p<0.001). 2. The capacitance of the gingival fluid of the periodontal disease group was markedly higher than for the normal group, and increased with the progression of the disease (p<0.01). 3. This new device features automatic digital display of the capacitance of the gingival fluid by simply inserting the tip of the probe into the periodontal pocket. Further, it is capable of accurately measuring the fluid, and has been shown to be fast, easy, precise and convenient. | |||||||
書誌情報 |
松本歯学 巻 12, 号 3, p. 281-287, 発行日 1986-12-31 |
|||||||
出版者 | ||||||||
出版者 | 松本歯科大学学会 | |||||||
ISSN | ||||||||
収録物識別子タイプ | ISSN | |||||||
収録物識別子 | 0385-1613 | |||||||
書誌レコードID | ||||||||
収録物識別子タイプ | NCID | |||||||
収録物識別子 | AN00232590 | |||||||
フォーマット | ||||||||
内容記述タイプ | Other | |||||||
内容記述 | application/pdf | |||||||
著者版フラグ | ||||||||
出版タイプ | VoR | |||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |