WEKO3
アイテム
Endocaterの臨床使用経験について
https://mdu.repo.nii.ac.jp/records/1327
https://mdu.repo.nii.ac.jp/records/1327e0d7c29f-1de8-40e1-9708-fba617d32bfb
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | Journal Article(1) | |||||||
---|---|---|---|---|---|---|---|---|
公開日 | 2012-05-24 | |||||||
タイトル | ||||||||
タイトル | Endocaterの臨床使用経験について | |||||||
言語 | ||||||||
言語 | jpn | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | 電気的根管長測定 | |||||||
キーワード | ||||||||
言語 | en | |||||||
主題Scheme | Other | |||||||
主題 | Endocater | |||||||
キーワード | ||||||||
言語 | en | |||||||
主題Scheme | Other | |||||||
主題 | apical seat | |||||||
資源タイプ | ||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||
資源タイプ | journal article | |||||||
その他(別言語等)のタイトル | ||||||||
その他のタイトル | Clinical Evaluation of Endocater | |||||||
著者 |
安田, 英一
× 安田, 英一
|
|||||||
抄録 | ||||||||
内容記述タイプ | Abstract | |||||||
内容記述 | Endocater, the newest electric root canal measuring device, was clinically evaluated on pulpectomy cases. Root Canal Meter was employed as control. The results were as follows: 1. The hand reamer was inserted into the root canal, of which most of the pulp had been previously removed, and the root canal length was measured by Endocater according to the manufacturer's instruction. In 12 (root canals) out of 48 cases, the reamer tips were between 0.2mm and 0.5mm shorter than the root canal length measured by Root Canal Meter at 40μA. In 10 cases, they were between 0.6mm and 2.8mm shorter than the root canal length at 40μA. In the remaining 26 cases, they were more than 3.8mm shorter than the root canal length at 40μA. 2. The cases in which the meter readings of the Endocater -with the working length shortened 1.0mm of the 40μA length- were between -3.0mm and +3.0mm from the central line of the meter, were 38 out of 55 cases (69.0%) at the time of pulp removal, and 47 out of 57 cases (82.5%) at the beginning of the next appointment after the pulpectomy. At this working length, the meter readings of the Root Canal Meter scattered from 28.0μA to 39.0μA, and 78.2% of the pulp removal time or 82.5% of the next appointment were included in this range. 3. Apical seat formation was evaluated by examining the location of master corn tips using X-ray dental photographs taken immediately after the root canal filling. In 39 out of 52 cases (75.0%), apical seats were formed in the range of 0.6mm to 1.2mm short of the root apex. Another 10 cases had apical seats formed between 1.4mm and 2.8mm short of the root apex. 8 cases failed in apical seat formation. | |||||||
書誌情報 |
松本歯学 巻 12, 号 1, p. 34-41, 発行日 1986-04-30 |
|||||||
出版者 | ||||||||
出版者 | 松本歯科大学学会 | |||||||
ISSN | ||||||||
収録物識別子タイプ | ISSN | |||||||
収録物識別子 | 0385-1613 | |||||||
書誌レコードID | ||||||||
収録物識別子タイプ | NCID | |||||||
収録物識別子 | AN00232590 | |||||||
フォーマット | ||||||||
内容記述タイプ | Other | |||||||
内容記述 | application/pdf | |||||||
著者版フラグ | ||||||||
出版タイプ | VoR | |||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |