抄録 | ||||||||
内容記述タイプ | Abstract | |||||||
内容記述 | For the dental clinic, the accurate evaluation of color tones of the teeth and of the oral mucous membrane is very significant. Using Model SF65 D-A and a large integral globe model, made by the author, the inner illuminance was measured. The result that the source of light within the integral calculus globe and the reflection were soft and homogeneous was successful. The details were as follows: 1) On the integral calculus globe Model SF65 D-A, the average value of the source of light D<65> was 1176 Lx, and the average value of the source of light A was 838 Lx. The average value of D_<65> and A together was 2020 Lx. The illuminance was homogeneous on all parts. 2) D_<65> was a daylight lamp and A was reddish one. By adding light A to light D_<65>, a reddish daylight, being diffused and soft, was obtained. 3) The reflection light on an integral calculus globe model, painted the surface with a titanium-dioxide (rutile type) emulsion paint, from 11 lamps was 1500~2000 Lx and was completely diffused and homogeneous. 4) The integral calculus globe did not cause any special noise but a little resound was felt at the center. 5) The calculation formula of the illuminance in the integral calculus globe is E (a, b)=2πI/√<a^2+b^2-a^2b^2> ln (1+√<a^2+b^2-a^2b^2>/1+√<a^2+b^2-a^2b^2>) and with the exception of the places near the wall, the illuminance is approximately homogeneous. 6) Based upon above mentioned results a clinic room in an integral calculus globe was built. The source of light will be D_<65> daylight and A light. On the inner side a titanium-dioxide (rutile type) emulsion paint will be painted. As a result, the source of light will be a soft and homogeneous reflection light. | |||||||
書誌情報 |
松本歯学 巻 6, 号 2, p. 179-188, 発行日 1980-12-31 |
|||||||
出版者 | ||||||||
出版者 | 松本歯科大学学会 | |||||||
ISSN | ||||||||
収録物識別子タイプ | ISSN | |||||||
収録物識別子 | 0385-1613 | |||||||
書誌レコードID | ||||||||
収録物識別子タイプ | NCID | |||||||
収録物識別子 | AN00232590 | |||||||
フォーマット | ||||||||
内容記述タイプ | Other | |||||||
内容記述 | application/pdf | |||||||
著者版フラグ | ||||||||
出版タイプ | VoR | |||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |