積分球診療室の光学的研究第3報 積分球内照度と疲労度について
https://mdu.repo.nii.ac.jp/records/286
https://mdu.repo.nii.ac.jp/records/2865ee155e1-9af7-4e67-ab11-de94bf832b34
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | Journal Article(1) | |||||||
---|---|---|---|---|---|---|---|---|
公開日 | 2012-05-23 | |||||||
タイトル | ||||||||
タイトル | 積分球診療室の光学的研究第3報 積分球内照度と疲労度について | |||||||
言語 | ||||||||
言語 | jpn | |||||||
資源タイプ | ||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||
資源タイプ | journal article | |||||||
その他(別言語等)のタイトル | ||||||||
その他のタイトル | An Optical Study of an Integral Calculus Globe Clinic Room Third Report: On the illuminance within the integral calculus globe and the degree of fatigue | |||||||
著者 |
橋口, 綽徳
× 橋口, 綽徳
|
|||||||
抄録 | ||||||||
内容記述タイプ | Abstract | |||||||
内容記述 | As a result of repeated experiments, it is clear that within the integral calculus globe, it is possible to obtain a homogeneous light which causes the least fatigue. After four persons had read some books for one hour per person inside the integral calculus globe clinic room, their degree of fatigue were measured by using the flicker fatigue-measuring instrument. Preceding this experiment, the four testees were tested three times daily, that is, every morning, daytime and night, by this flicker fatigue-measuring instrument for ten days, in order to know the type of their most efficient working hours, namely: morning-type, night-type etc, before the experiment was commenced. 1) The illuminance within the integral calculus globe clinic room model was 1950~2300lx between 0~40cm. The average illuminance at the position of 30cm was 2180lx. 2) The illuminance within the clinic room was 1720lx when all circuits are on, 1026lx in D_<65>+Daylight source of light, 1310lx in A source of light+Daylight source of light, 1270lx in A source of light+D_<65>. 3) The average standard deviation of flicker values were: Example A 0.99, Example B 0.95, Example C 1.18, Example D 1.38. Within the integral calculus globe clinic room model, there was no difference in fatigue before and after the operation. 4) The flicker value of one-hour reading within the integral calculus globe clinic room when the source of light was all circuit, D_<65>+Daylight, A Light+D_<65>, was +1.0~-1.2. This shows that 〓 difference is -0.3 and proves little degree of fatigue. Compared to this, when reading is done on an office desk with just one source of light, the value is -0.5~-2.5, which means that the average difference is -1.0. This indicates a strong fatigue when reading is done on an office desk. As a result of this, we may well assume that the integral calculus globe clinic room cause less fatigue. | |||||||
書誌情報 |
松本歯学 巻 7, 号 1, p. 87-94, 発行日 1981-06-30 |
|||||||
出版者 | ||||||||
出版者 | 松本歯科大学学会 | |||||||
ISSN | ||||||||
収録物識別子タイプ | ISSN | |||||||
収録物識別子 | 0385-1613 | |||||||
書誌レコードID | ||||||||
収録物識別子タイプ | NCID | |||||||
収録物識別子 | AN00232590 | |||||||
フォーマット | ||||||||
内容記述タイプ | Other | |||||||
内容記述 | application/pdf | |||||||
著者版フラグ | ||||||||
出版タイプ | VoR | |||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |