WEKO3
アイテム
デジタルカメラを用いた顔面計測法に関する研究 : 垂直的顎間関係決定法の検討
https://mdu.repo.nii.ac.jp/records/444
https://mdu.repo.nii.ac.jp/records/4440aeada49-fcfa-45fa-bb42-57ecb1720b5a
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | Journal Article(1) | |||||||
---|---|---|---|---|---|---|---|---|
公開日 | 2012-05-24 | |||||||
タイトル | ||||||||
タイトル | デジタルカメラを用いた顔面計測法に関する研究 : 垂直的顎間関係決定法の検討 | |||||||
言語 | ||||||||
言語 | jpn | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | 垂直的顎間関係 | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | 顔面計測 | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | デジタルカメラ | |||||||
資源タイプ | ||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||
資源タイプ | journal article | |||||||
その他(別言語等)のタイトル | ||||||||
その他のタイトル | Measurement of facial morphology to determine occlusal vertical dimension : Application of digital camera to the measurement of facial morphology | |||||||
著者 |
中塚, 佑介
× 中塚, 佑介
|
|||||||
抄録 | ||||||||
内容記述タイプ | Abstract | |||||||
内容記述 | Purpose: The measurement of facial morphology in order to determine occlusal vertical dimension has been considered important in fabricating complete denture. The present study obtained basic data about the applicability of a facial morphological measuring method using digital camera pictures in comparison with the standard method by using dental calipers. Methods: Thirty male clinical staff (25-47 years old) with healthy natural dentition were recruited as subjects. Digital pictures of the subjects were taken with each in the frontal direction with the mandible at the intercuspal position. Using an image processing program, both the distances from the pupil of the eye to the parting line of the lips and from the base of the nose to the lower edge of the mandible were measured. These distances were compared with those measured directly on the subject's face using dental calipers. Results: On the digital pictures, both distances from the pupil of the eye to the rima oris and from the base of the nose to the lower edge of the mandible were 72.2±3.4mm and 66.1±3.9mm on the average, respectively. Moreover, regarding the distance from the base of the nose to the lower edge of the mandible, simple regression analysis demonstrated that values derived from the digital camera were positively correlated with those from dental calipers (R^2=0.51, p<0.01). Conclusions: Neither result derived from the methods examined in this study fit the theory proposed by Willis. The possibility of applying a digital camera to the measurement of facial morphology was indicated. | |||||||
書誌情報 |
松本歯学 巻 33, 号 2, p. 167-171, 発行日 2007-08-31 |
|||||||
出版者 | ||||||||
出版者 | 松本歯科大学学会 | |||||||
ISSN | ||||||||
収録物識別子タイプ | ISSN | |||||||
収録物識別子 | 0385-1613 | |||||||
書誌レコードID | ||||||||
収録物識別子タイプ | NCID | |||||||
収録物識別子 | AN00232590 | |||||||
フォーマット | ||||||||
内容記述タイプ | Other | |||||||
内容記述 | application/pdf | |||||||
著者版フラグ | ||||||||
出版タイプ | VoR | |||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |