WEKO3
アイテム
下顎枝矢状分割法における骨片固定法の違いによる術後成績の比較検討
https://mdu.repo.nii.ac.jp/records/470
https://mdu.repo.nii.ac.jp/records/47080bc314f-d59c-409b-a234-c6672d9fbd9b
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| アイテムタイプ | Journal Article(1) | |||||||
|---|---|---|---|---|---|---|---|---|
| 公開日 | 2012-05-24 | |||||||
| タイトル | ||||||||
| タイトル | 下顎枝矢状分割法における骨片固定法の違いによる術後成績の比較検討 | |||||||
| 言語 | ||||||||
| 言語 | jpn | |||||||
| キーワード | ||||||||
| 主題Scheme | Other | |||||||
| 主題 | 下顎枝矢状分割法 | |||||||
| キーワード | ||||||||
| 主題Scheme | Other | |||||||
| 主題 | オトガイ神経麻痺 | |||||||
| キーワード | ||||||||
| 主題Scheme | Other | |||||||
| 主題 | 顎関節障害 | |||||||
| キーワード | ||||||||
| 主題Scheme | Other | |||||||
| 主題 | 骨格性後戻リ | |||||||
| 資源タイプ | ||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||
| 資源タイプ | journal article | |||||||
| その他(別言語等)のタイトル | ||||||||
| その他のタイトル | Comparative study of postoperative evaluation by fixation methods in sagittal splitting ramus osteotomy | |||||||
| 著者 |
富田, 郁雄
× 富田, 郁雄
|
|||||||
| 抄録 | ||||||||
| 内容記述タイプ | Abstract | |||||||
| 内容記述 | We retrospectively evaluated the results of mandibular setback by sagittal splitting ramus osteotomy performed by our department between 1989 at 2005. Two hundred-one patients were grouped into three categories; nonrigid fixation using intraosseous wiring with a mean intermaxillary fixation (IMF) period of 38.9 days (52 cases), rigid fixation consisting of positioning screw (18 cases, mean IMF period; 21.7 days) and mini-plate (131 cases, mean IMF period; 21.4 days) were reviewed. Regarding functional disturbance after surgery, a higher incidence of neurosensory deficiencies of mental nerve and TMJ disorders were observed in cases in which positioning screw or mini-plate were used, in comparison with wire osteosynthesis cases. To determine skeletal relapse within 12 months after surgery, lateral cephalograms were employed for cases in which the amount of R-, L- set back differences were less than 3mm. The relapse was minimal in positioning screw cases, while the mini-plate fixation showed a greater amount of relapse compared to wire fixation, suggesting that three-dimensional repositioning of temporomandibular joint and longer term intermaxillary fixation were useful to obtain skeletal stability. | |||||||
| 書誌情報 |
松本歯学 巻 32, 号 3, p. 199-204, 発行日 2006-12-31 |
|||||||
| 出版者 | ||||||||
| 出版者 | 松本歯科大学学会 | |||||||
| ISSN | ||||||||
| 収録物識別子タイプ | ISSN | |||||||
| 収録物識別子 | 0385-1613 | |||||||
| 書誌レコードID | ||||||||
| 収録物識別子タイプ | NCID | |||||||
| 収録物識別子 | AN00232590 | |||||||
| フォーマット | ||||||||
| 内容記述タイプ | Other | |||||||
| 内容記述 | application/pdf | |||||||
| 著者版フラグ | ||||||||
| 出版タイプ | VoR | |||||||
| 出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||