WEKO3
アイテム
矯正用固定源に用いたインプラント周囲骨組織と歯の移動効果
https://mdu.repo.nii.ac.jp/records/577
https://mdu.repo.nii.ac.jp/records/57716441723-2ccc-4271-a2a0-9f308281e440
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | Journal Article(1) | |||||||
---|---|---|---|---|---|---|---|---|
公開日 | 2012-05-24 | |||||||
タイトル | ||||||||
タイトル | 矯正用固定源に用いたインプラント周囲骨組織と歯の移動効果 | |||||||
言語 | ||||||||
言語 | jpn | |||||||
キーワード | ||||||||
言語 | en | |||||||
主題Scheme | Other | |||||||
主題 | orthodontics | |||||||
キーワード | ||||||||
言語 | en | |||||||
主題Scheme | Other | |||||||
主題 | tooth movement | |||||||
キーワード | ||||||||
言語 | en | |||||||
主題Scheme | Other | |||||||
主題 | implant | |||||||
キーワード | ||||||||
言語 | en | |||||||
主題Scheme | Other | |||||||
主題 | anchorage | |||||||
キーワード | ||||||||
言語 | en | |||||||
主題Scheme | Other | |||||||
主題 | force system | |||||||
資源タイプ | ||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||
資源タイプ | journal article | |||||||
その他(別言語等)のタイトル | ||||||||
その他のタイトル | The influence of orthodontic tooth movement using mini-titan implants as anchorage device | |||||||
著者 |
影山, 徹
× 影山, 徹
|
|||||||
抄録 | ||||||||
内容記述タイプ | Abstract | |||||||
内容記述 | The purpose of present study was to determine the anchorage potential of mini-titanium implant for orthodontic tooth movement in two Beagle dogs. Extracted upper and lower second premolar to maintain the orthodontic mesial tooth movement of third premolar. Sixteen mini-titanium implants (1.0 x 5.0mm; eight loaded and eight control) were placed bilaterally in healed upper and lower jaw bone. After twelve weeks, orthodontic device was applied to upper and lower canine, third and fourth premolars. Third premolars were retracted mesialy on 200g of continuous force for entire sixteen weeks by Ni-Ti closed coilspring that were placed between mini-titanium implant and third premolar. Fluorochrome bone labels (Tetracycline, Calcein blue, Alizarine red and Xylene orange) were injected during orthodontic force application to determine the remodeling at bone-implant interface and effect of tooth movement. Bone contact, remodeling at surrounding bone-implant interface and environment of non-movement and movement tooth were observed by back scattered electron micro images (BSE), electron prove micro analyzer (EPMA), laser scanning micro images (LSM) and light micro scope images. The result of our study showed upper and lower third premolars were bodily moved mesialy 3.5mm on the average and non-loaded control tooth were remain in the force system without any anchorage. Bone contact at surrounding bone-implant interface maintained rigid osseointegration. Slight active bone remodeling was observed at surrounding bone-implant interface during orthodontic force application than non retracted control implant. We concluded that the mini-titanium implants successfully resisted the orthodontic load and could be maintain the tooth movement or remain in orthodontic force system. | |||||||
書誌情報 |
松本歯学 巻 29, 号 3, p. 272-287, 発行日 2003-12-31 |
|||||||
出版者 | ||||||||
出版者 | 松本歯科大学学会 | |||||||
ISSN | ||||||||
収録物識別子タイプ | ISSN | |||||||
収録物識別子 | 0385-1613 | |||||||
書誌レコードID | ||||||||
収録物識別子タイプ | NCID | |||||||
収録物識別子 | AN00232590 | |||||||
フォーマット | ||||||||
内容記述タイプ | Other | |||||||
内容記述 | application/pdf | |||||||
著者版フラグ | ||||||||
出版タイプ | VoR | |||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |