ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 松本歯学(Print edition:ISSN 0385-1613 Online edition:ISSN 2188-7233)
  2. 22巻(1996)
  3. 2号

Preliminary Report on the Jaw Tracking System with Six Degrees of Freedom (MM-JI-E, Jaw tracking system)

https://mdu.repo.nii.ac.jp/records/819
https://mdu.repo.nii.ac.jp/records/819
b7daa12a-3704-4117-966a-023f8219e618
名前 / ファイル ライセンス アクション
matsumoto_shigaku_22-02-06.pdf matsumoto_shigaku_22-02-06.pdf (668.9 kB)
Item type Journal Article(1)
公開日 2012-05-24
タイトル
タイトル Preliminary Report on the Jaw Tracking System with Six Degrees of Freedom (MM-JI-E, Jaw tracking system)
言語 en
言語
言語 eng
キーワード
言語 en
主題Scheme Other
主題 jaw movement
キーワード
言語 en
主題Scheme Other
主題 mandibular movement analyzing system
キーワード
言語 en
主題Scheme Other
主題 six degree of freedom
キーワード
言語 en
主題Scheme Other
主題 supporting zone
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
その他(別言語等)のタイトル
その他のタイトル 6自由度顎運動測定装置の試用
著者 KUROIWA, AKIHIRO

× KUROIWA, AKIHIRO

KUROIWA, AKIHIRO
KOZAWA, TAKESHI
IGARASHI, YOSHIMASA
SUGITOU, SHOHEI
ARAKAWA, HITOSHI
INOUE, YOSHIHISA
YONEDA, TAKANORI

抄録
内容記述タイプ Abstract
内容記述 The purpose of this study was to quantitatively analyze the mandibular movement by the Jaw tracking system with six degree of freedom (MM-JI-E). Displacements of the condyles under maximum clenching with successive loss of mandibular supporting zones were measured. The patient, a 29-year-old man, had been treated at an orthodontic clinic between 1994 and 1997, and temporary full coverage crowns were fabricated on four molars of the lower jaw. He showed no signs of abnormality of stomatognathic function. We measured the jaw movements with MM-JI-E, removing the crowns from the distal end of molars to the mesial. The condylar displacement values were displayed and calculated by the measurement of mandibular movement. When the supporting zones were reduced successively, both condyles moved upwards and slightly forwards (87-117°). The maximal condylar displacement values was 700μm without any support in the molars. We compared the measurements of MM-JI-E with those obtained with another jaw movement tracking system (Bio Pack), with three degree of freedom. The maximum opening paths in sagittal border movement were compared for the two measurement systems. The Bio Pack showed the deflection of the path of anterior maximum opening due to electronic error.
書誌情報 松本歯学

巻 22, 号 2, p. 161-166, 発行日 1996-08-31
出版者
出版者 松本歯科大学学会
ISSN
収録物識別子タイプ ISSN
収録物識別子 0385-1613
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00232590
フォーマット
内容記述タイプ Other
内容記述 application/pdf
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 08:29:10.494170
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3