WEKO3
アイテム
ミリング型セラミックインレーシステム"セレイ"の評価 : 第2報 窩壁適合性について
https://mdu.repo.nii.ac.jp/records/866
https://mdu.repo.nii.ac.jp/records/866c9853e93-04c3-44a4-8ea8-8c4878bbbcec
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | Journal Article(1) | |||||||
---|---|---|---|---|---|---|---|---|
公開日 | 2012-05-24 | |||||||
タイトル | ||||||||
タイトル | ミリング型セラミックインレーシステム"セレイ"の評価 : 第2報 窩壁適合性について | |||||||
言語 | ||||||||
言語 | jpn | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | セラミックインレー | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | CELAY | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | 窩壁適合性 | |||||||
資源タイプ | ||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||
資源タイプ | journal article | |||||||
その他(別言語等)のタイトル | ||||||||
その他のタイトル | An Evaluation of Milling Ceramic Inlay System, CELAY^[○!R] : Part. 2 Marginal adaptaion and internal fit of CELAY inlay | |||||||
著者 |
山本, 昭夫
× 山本, 昭夫
|
|||||||
抄録 | ||||||||
内容記述タイプ | Abstract | |||||||
内容記述 | As the demand for aesthetic restorations has increased in the past few years, tooth color materials have been used frequently in posterior teeth. Ceramics are widely used as dental restorative materials. The CELAY system that creates a ceramic inlay by a milling technique has been developed and introduced recently. The purpose of this study was to investigate the marginal adaptation and internal fit of ceramic inlays made using the CELAY system. Twenty extracted upper premolars were used. Only one clinician prepared all twenty box-shaped class II (MO) cavities to make the cavities uniform. The fabricated ceramic inlay that each of five ceramic inlays made by four clinicians whose clinical experience period differed was luted in the individual cavity with a dual-cured composite resin cement. Then all of them were cut mesio-distally through the center of the inlay. The cut surface of the specimens were observed under a profile projector. Marginal adaptation and internal fit were defined as inter facial distances between a ceramic inlay and cavity wall, and measured at nine preselected points. The following results were obtained; 1) The average gap width for all measured points was 170.2±111.8μm. 2) Statistical analysis showed that there were no significant differences among the nine preselected points. But there were significant differences (P<0.01) among the operators. 3) The fitness of the ceramic inlay to the cavity wall had decreased in the order of the central cavity wall, the margin of the cavity and line angle of the cavity, when compared with the nine measuring points. It may be concluded that if the operator is greatly experienced in the ways of the CELAY system he can reduce operating time and can improve adaptation. | |||||||
書誌情報 |
松本歯学 巻 21, 号 2, p. 155-161, 発行日 1995-08-30 |
|||||||
出版者 | ||||||||
出版者 | 松本歯科大学学会 | |||||||
ISSN | ||||||||
収録物識別子タイプ | ISSN | |||||||
収録物識別子 | 0385-1613 | |||||||
書誌レコードID | ||||||||
収録物識別子タイプ | NCID | |||||||
収録物識別子 | AN00232590 | |||||||
フォーマット | ||||||||
内容記述タイプ | Other | |||||||
内容記述 | application/pdf | |||||||
著者版フラグ | ||||||||
出版タイプ | VoR | |||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |