印象材と石膏の組み合わせによる模型の精度
https://mdu.repo.nii.ac.jp/records/951
https://mdu.repo.nii.ac.jp/records/951d1bd94fb-1152-4d73-9f1b-2c37f800ffbe
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | Journal Article(1) | |||||||
---|---|---|---|---|---|---|---|---|
公開日 | 2012-05-24 | |||||||
タイトル | ||||||||
タイトル | 印象材と石膏の組み合わせによる模型の精度 | |||||||
言語 | ||||||||
言語 | jpn | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | アルジネート印象材 | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | 寸法変化 | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | 細線再現性 | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | 表面あらさ | |||||||
資源タイプ | ||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||
資源タイプ | journal article | |||||||
その他(別言語等)のタイトル | ||||||||
その他のタイトル | Accuracy of the Cast on the Combination of Impression Materials with Dental Plasters | |||||||
著者 |
田坂, 裕子
× 田坂, 裕子
|
|||||||
抄録 | ||||||||
内容記述タイプ | Abstract | |||||||
内容記述 | Compatibility of five alginate impression materials with two dental plasters and five dental stones were evaluated for dimensional change, detail reproduction and surface roughness. The specimens were stored either in air (23℃±2℃, 60%±10% humidity) or in 100% relative humidity for 30, 60, or 120 minutes after impression was removed. The effect of environmental factors during setting was examined. Four elastomeric impression materials were also examined for comparison. The results obtained were as follows; 1. For impressions stored in air, there were significant differences in the dimensional change of cast in each product. However, there were few differences observed in 100% humidity. 2. Regarding dimensional change, the limit of sustained impression time was 30 minutes. 3. The detail reproduction was inferior with time passage after the impression was removed. 4. Surface roughness decreased with time passage. 5. The surface of casts of some impressions produced in 100% humidity were rougher than those produced in air. 6. It is generally said that to keep impressions in 100% humidity is the optimal method. However, some materials were not appropriate for this method. 7. Elastomeric impression materials were stabile in dimensional accuracy and detail reproduction up to 120 minutes. 8. Surface roughness of casts made from elastomeric impression material decreased with time passage. | |||||||
書誌情報 |
松本歯学 巻 19, 号 3, p. 265-272, 発行日 1993-12-31 |
|||||||
出版者 | ||||||||
出版者 | 松本歯科大学学会 | |||||||
ISSN | ||||||||
収録物識別子タイプ | ISSN | |||||||
収録物識別子 | 0385-1613 | |||||||
書誌レコードID | ||||||||
収録物識別子タイプ | NCID | |||||||
収録物識別子 | AN00232590 | |||||||
フォーマット | ||||||||
内容記述タイプ | Other | |||||||
内容記述 | application/pdf | |||||||
著者版フラグ | ||||||||
出版タイプ | VoR | |||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |