WEKO3
アイテム
積分球診寮室の光学的研究 : 第1報,積分球診療室の作製とその照度について
https://mdu.repo.nii.ac.jp/records/269
https://mdu.repo.nii.ac.jp/records/26943f55ac3-4bfb-4fda-a33c-11c8218fcb05
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | Journal Article(1) | |||||||
---|---|---|---|---|---|---|---|---|
公開日 | 2012-05-23 | |||||||
タイトル | ||||||||
タイトル | 積分球診寮室の光学的研究 : 第1報,積分球診療室の作製とその照度について | |||||||
言語 | ||||||||
言語 | jpn | |||||||
資源タイプ | ||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||
資源タイプ | journal article | |||||||
その他(別言語等)のタイトル | ||||||||
その他のタイトル | An Optical Study on a Clinic Room in the Integral Calculus Globe First Report : On the plan of the integral calculus globe and its illuminance | |||||||
著者 |
橋口, 綽徳
× 橋口, 綽徳
|
|||||||
抄録 | ||||||||
内容記述タイプ | Abstract | |||||||
内容記述 | 1) A clinic room in an integral calculus globe was made according to the basic experiments. By measuring the illuminance it was found that a diffused natural light having no shadows and soft light equally to daylight was succeeded to obtain. The light showed the same illuminance as the light from a north window in the daytime (1800~2000Lx) which is the best condition to observe the color tone of the teeth. This light is also suitable for the health of the eyes during long-time treatment. It is, moreover, good for the psychological stability of the patients. 2) Results of a comparison measurement of the illuminance showed that the lightest was the whole circuit, followed by Light A, Daylight, Light D<65>. 3) Individually used, Light A, Daylight, Light D<65> showed a fixed and homogeneous illuminance in all parts, but when the all Lights were used together, the illuminance value changed to unstable. 4) When medical instruments were carried in the room the illuminance of the integral calculus globe declined. 5) As for the floor, P-tiles had a lighter illuminance in comparison to grey carpet. 6) It was interesting that when medical instruments were carried into the integral calculus globe, the value of daylight fluorescent light became unstable. 7) The average illuminance of the preventive treatment room, which was used for the control, was 563 Lx when it was measured in 6 defferent places. | |||||||
書誌情報 |
松本歯学 巻 6, 号 2, p. 189-202, 発行日 1980-12-31 |
|||||||
出版者 | ||||||||
出版者 | 松本歯科大学学会 | |||||||
ISSN | ||||||||
収録物識別子タイプ | ISSN | |||||||
収録物識別子 | 0385-1613 | |||||||
書誌レコードID | ||||||||
収録物識別子タイプ | NCID | |||||||
収録物識別子 | AN00232590 | |||||||
フォーマット | ||||||||
内容記述タイプ | Other | |||||||
内容記述 | application/pdf | |||||||
著者版フラグ | ||||||||
出版タイプ | VoR | |||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |