タイトル | ||||||||
タイトル | 純チタンの鋳造性に関する研究(第2報) : 埋没材と鋳型温度の違いが鋳込率に及ぼす影響について | |||||||
言語 | ||||||||
言語 | jpn | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | チタン | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | 鋳型温度 | |||||||
キーワード | ||||||||
主題Scheme | Other | |||||||
主題 | 鋳造性 | |||||||
資源タイプ | ||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||
資源タイプ | journal article | |||||||
その他(別言語等)のタイトル | ||||||||
その他のタイトル | Studies on the Castability of Pure Titanium (Part 2) : Effects of difference of casting mold and mold temperature on the castability of titanium | |||||||
著者 |
堀口, 英子
× 堀口, 英子
|
|||||||
抄録 | ||||||||
内容記述タイプ | Abstract | |||||||
内容記述 | The purpose of this study was to evaluate titanium castability with a vacuum-pressure type casting machine under different mold temperatures. We employed two types of cement bonded investments in this study. One of the casting molds was "Titavest MZ" for metal frame work, and the other was "Titavest CB" for crown and bridge work. The molds temperature were prepared at room temperature, 300℃, 600℃, and 900℃ for each, respectively. When the mold temperature was set at a high range with "Titavest MZ", high percentage of castability was gained. Mold temperature at "Titavest MZ" showed a statistically significant correlation on the castability (p<0.1). On the other hand, "Titavest CB" showed high percentage of castability under every condition. Above results were not quitely explained only by this present study. But, it was realized that at least two different types of investing materials were present; one which had a positive relation to the mold temperature, and the other which had a negative one in relation to the pure titanium castsbility. | |||||||
書誌情報 |
松本歯学 巻 21, 号 2, p. 166-170, 発行日 1995-08-30 |
|||||||
出版者 | ||||||||
出版者 | 松本歯科大学学会 | |||||||
ISSN | ||||||||
収録物識別子タイプ | ISSN | |||||||
収録物識別子 | 0385-1613 | |||||||
書誌レコードID | ||||||||
収録物識別子タイプ | NCID | |||||||
収録物識別子 | AN00232590 | |||||||
フォーマット | ||||||||
内容記述タイプ | Other | |||||||
内容記述 | application/pdf | |||||||
著者版フラグ | ||||||||
出版タイプ | VoR | |||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |